How to Keep Your Home Warm During Sydney Winters

Double Glazing Window

How to Keep Your Home Warm During Sydney Winters

Let’s face it. The past 18 months have created a pervasive stigma about getting sick. All of a sudden, Sydneysiders have felt an internalised feeling of urgency to follow rules their mum told them, like making sure their clothes aren’t damp and that their hair isn’t wet before they go to bed.

While the factors listed won’t contribute to anyone in your home falling ill, a significant drop in heat and body temperature will, as this environment promotes the spread of viruses like the common cold and suppresses the immune system making it especially important to keep your house warm. The costs savings associated with helping your house heat up quickly and keep warm for hours won’t just help you from a health standpoint but will help you save money on your electricity bill as well. With morning temperatures falling to record lows this winter, we’ve created a guide to keep your Sydney home warm.

Concentrate Heat into The Rooms You’re Using

While ideally, everyone wants to keep their entire house warm, the most cost-effective and time-efficient way to keep a property warm in winter is to pick specific sections of your home to localise heat within. The logical tip is to focus on the rooms that people in your house are likely to be using the most like your bedroom or central room like living room, as the heat will circulate around the house. In the meantime, keeping doors closed in peripheral rooms of the house will lock heat into the most important areas such as the kitchen, dining room and living room within your home.

Check Windows and Doors Insulation

Checking windows and doors insulation in your house is an important part of keeping it warm, as most houses leak a significant amount of heat in the winter through windows and doors. As we’ve discussed in a previous article, homes that lack window and door insulation can cause massive surges in the power bill, but understanding how heat loss is allocated can provide great insights into how to keep your house warm. The Australian government recommends checking ceilings, walls, window insulation, door insulation and your floors for adequate insulation as this accounts for almost all heat loss. Should your walls or ceiling need insulation, undergoing renovations and calling in a builder to install them will keep your house warm and cosy this winter. However, in cases of shoddy work and badly insulated windows and doors, replacing them completely maybe an expensive feat. Don’t worry, read on to find out a less expensive solution.

Use Double Glazed Windows

Another way to keep your house warm and cosy this winter is by utilising the benefits of double-glazed windows. Double glazed windows create a pocket of air between each windowpane, which drastically reduces the amount of heat that can escape through your window. Double glazed windows are a solid investment, as they provide year-round insulation. This means they provide tremendous value also in the summertime when you are trying to keep the heat out. While you might fear the disruption during installation to your home, a company like Magnetite offers retrofit double glazing, which allows the installation of an additional window onto your existing window, which is quick and easy thanks to the methods they use. Magnetite’s retrofit double-glazed window is fitted with a magnetic seal and acrylic glazing which creates a thermal insulation system that has the lowest air infiltration rate available and the best window insulation in Sydney – creating thermal comfort for your home.

Acoustic Weather Seals

Finally, a significant amount of heat in your home escapes from gaps under doors that are not fitted with a weather seal. With draughts through windows and doors accounting for 15% – 25% of heating and cooling, seals are an effective way to insulate your home in winter and summer. Magnetite Sydney offers premium weather seals that, like our windows, can be retrofitted to your existing doors, so that you don’t have to worry about a lengthy installation period when trying to plug the gaps that heat is escaping from.

If you need any advice on how you can keep your home warm this winter or you’re interested in learning more about Magnetite products, get in contact with our Double-Glazing Sydney experts today.

  1. Conduction
    Heat moving through an object (i.e. heat will travel through an aluminium, or steel frame more easily than through a timber or PVC frame).
  2. Radiant heat
    Heat from the direct sun. It can pass through space until reflected or absorbed.
  3. Convection
    Heat flow resulting from air movement e.g. either 'natural' convection - warm air rises, or 'forced' convection - a breeze by a window, both can result in a draught by a window.
  4. Infiltration
    Air leaks around the frame, around the window sash and through the gaps in the movable window parts.

When evaluating your options to improve the thermal performance of your windows, the following double glazing key performance criteria should be considered:

  • U-Value (Uw) represents heat transfer through a window, irrespective of direct sunlight. The lower a window’s U-Value, the better the insulation performance.
  • Solar Heat Gain Coefficient (SHGC) measures the solar energy that passes through glazing. The lower the SHGC, the less solar heat is transmitted through a window.
  • Air Infiltration or leakage measures the rate at which air passes through gaps in window joins and seals. The lower the air infiltration, the better a window’s energy performance.

The Window Energy Rating Scheme (WERS) Thermal Performance

Aluminium Frame Windows

Glazing Type Cooling Stars Heating Stars Cool% Heat% Uw SHGC
Single glazed 3mm clear glass* half blue star red starhalf red star 7.4 0.77
Single glazed 3mm clear glass &
4.5mm Magnetite
blue starblue starhalf blue star red starred starred starred starred starhalf red star 35% 59% 2.9 0.67

Timber Frame Windows

Glazing Type Cooling Stars Heating Stars Cool% Heat% Uw SHGC
Single glazed 3mm clear glass* blue starhalf blue star red starred starred starhalf red star 20% 28% 5.5 0.69
Single glazed 3mm clear glass &
4.5mm Magnetite
blue starblue starhalf blue star red starred starred starred starred starred star 37% 61% 2.6 0.66
Single glazed 3mm clear glass with
Solartite** and 4.5mm Magnetite
blue starblue starblue starblue starblue starblue starhalf blue star red starred starred starred starhalf red star 76% 45% 1.8 0.20

 

*WERS standard typical industry window
**Solartite is a range of high performance window film. The window tested above has Solartite’s low-e film.


Magnetite vs Traditional Double Glazing – What the experts says

Winter - the ideal situation is to let in as much of the sun's heat and then trap it inside to maintain a comfortable environment in your home or office. This will also significantly reduce heating costs and saves you money. The ideal window for winter will have a high SHGC to let the sun's heat in and a low U-Value to prevent the heat from escaping. Clear windows without shading films are better suited for winter climates.

Compared with traditional double-glazing, Magnetite’s double-glazing solution can provide better results during winter or for cold climate areas such as Canberra, the Adelaide Hills and Blue Mountains.

Magnetite's clear acrylic window panels allow the direct heat from the sun's rays to enter the building and once inside, Magnetite's superior magnetic seals retain the heat, giving Magnetite an advantage over conventional operating windows.

Glazing Type Cooling Stars Heating Stars Cool% Heat% Uw SHGC AI
Double Glazed 3mm clear glass/12mm air
gap/3mm clear glass IGU (Insulated Glass Unit)*
blue starblue starhalf blue star red starred starred starred starred starhalf red star 40% 55% 3.0 0.61 5.0
Single glazed 3mm clear glass &
4.5mm Magnetite
blue starblue starhalf blue star red starred starred starred starred starred star 37% 61% 2.6 0.66 0.5

 

*WERS standard typical industry window

Summer - the ideal situation is to minimize the heat coming in from outside and prevent the cool air inside from escaping through the window. This will make your home more comfortable and reduce your air-conditioning costs. The ideal window for summer, or for a large west-facing window, will have a low SHGC to limit the heat from the sun's direct rays, as well as, a low U-Value to prevent the heat in the air outside from moving through the window and warming the cool conditioned air inside. It is better to have a shading film on the first (outer) glass pane to limit the heat that enters the double glazed unit.

The combination of Magnetite retrofit double glazing and Solartite outperforms the traditional insulated glass unit for hot climate. Magnetite fit over an existing window with reflective film will give better summer heat control than a double-glazed window with supertoned glass.

The Magnetite system stops the conduction and convection of heat better than glass windows giving superior results for summer conditions. Combined with a film or a shading device, Magnetite is the ideal solution for the hot Australian conditions.

Glazing Type Cooling Stars Heating Stars Cool% Heat% Uw SHGC AI
Double Glazed 5mm Supertoned glass/6mm
air gap/5mm clear glass IGU (Insulated Glass Unit)*
blue starblue starblue starhalf blue star red starred starred starred starhalf red star 54% 425% 3.30 0.461 5.0
Single glazed 3mm glass Solartite**
and 4.5mm Magnetite
blue starblue starblue starblue starblue starhalf blue star red starred starred starred star 73% 38% 2.4 0.19 0.5

 

*WERS standard typical industry window
**Solartite is a range of high performance window film. The window tested above has Solartite’s low-e film.

Click here to view pdf version of Magnetite WERS test result.

Noise Reduction Technical Data and Results

Proven Results

Noise pollution is one the biggest problems faced in the cities today, particularly in a high-density living. Unwanted noise can be responsible for sleep loss and lack of concentration. This can lead to a deterioration of health through increased stress levels, headaches, high blood pressure and loss of hearing.

Noise penetrates windows through leaky seals or vibrations through the window structure. To reduce noise, a window should minimise air infiltration, hold enough weight to limit vibration and allow a large air cavity. This cavity, or air gap, is the key to secondary glazing.

Expert Advice:

CSIRO Research by John Davy shown an air cavity can effectively enhance sound insulation performance. The larger the air cavity the more noise the window system can reduce. Results show a wide air gap of 100-125mm will improve sound insulation by an average of 7dB(A) more than windows with a narrow gap of 8-13mm.

Window or Glass Door Type Total Glass Thickness (mm) Air Cavity Thickness (mm) Sound Insulation (dB)
Single Glaze 3mm 3 0 23
Single Glaze 6mm 6 0 27
Double Glaze Narrow Gap 9-12 8-13 31
Double Glaze Wide Gap 9-12 100-125 38

 

The human ear is less sensitive to low frequency sound. According to a study released by the CSIRO, the human ear needs a change of 3dB to detect a difference in noise levels and the human ear perceives a change of 10dB as a doubling or halving of the noise level.

If you double the thickness of glass in a window the noise level will decrease by 3dB the least amount possible to make a difference. If the glass is laminated there is no perceived difference in noise reduction.

National Acoustic Laboratory Testing:

Working with the principles of noise transfer, Magnetite® and Soundtite are designed for high performance, which is achieved by combining air tight seals with the ability to maximize an air cavity and the flexibility to vary glazing thickness to suit. Magnetite® is excellent at reducing general noise such as busy roads, commuter trains and noisy neighbours. Whereas, Soundtite works well to combat low frequencies noise such as garbage truck, freight trains or airplane during take-off and landing.

Test Code Material Tested Rw* Improvement
ATF 707 (test window) Aluminium sliding window, 3mm float glass with mohair seals 23 N/A
ATF 709 Test window, 100mm air gap and Magnetite System (4.5mm acrylic panel) 35 52%
ATF 1507 Test window, 100mm air gap and Magnetite System (10.0mm acrylic panel) 39 70%
ATF 817 Test window, 100mm air gap and Soundtite (6.38mm laminated glass) 41 78%

 

*The Weighted Sound Reduction Index (Rw) is a measure for sound insulation performance of a single building element such as windows. The higher the Rw rating, the better the sound insulation.